BIOSAFETY CABINET

At “Breath Air System LLP”, our Biosafety Cabinets (BSCs) offer top-tier protection for laboratory environments. Utilizing advanced air decontamination and negative pressure technology, our cabinets ensure safety for users, samples, and the surrounding environment. With a focus on personnel, product, and environmental protection, our BSCs maintain sterility and prevent cross-contamination. The downward laminar flow of HEPA-filtered air provides unparalleled product protection, minimizing the risk of contamination. By drawing airflow away from the operator and through HEPA filters, our cabinets guarantee a contaminant-free workspace.

We prioritize cutting-edge solutions to meet the evolving needs of laboratory safety and contamination control. Trust “Breath Air System LLP” for state-of-the-art biosafety solutions, securing a controlled environment for sensitive research and experimentation.

BCS Made in three different class types such as Class I, Class II & Class III; in which Class II is widely used in many applications because it provides protection to both product as well personnel.

Different Types of Class II BIOSAFETY Cabinet

  • Class II A1 - Minimum inflow velocity of 75 fpm, 70% of air is recirculated; 30% is ducted. The contaminated plenum is surrounded by the lab environment.

  • Class II A2 - minimum inflow velocity of 100 fpm, with a negative plenum surrounding the contaminated plenum. 70% of air is recirculated; 30% is ducted.

  • Class II B1 - Recirculated but Exhaust air have dedicated hard-ducted exhaust lines, with 70% air exhaust & 30% of Recirculation.

  • Class II B2 - does not Recirculation but Exhaust air have dedicated hard-ducted exhaust lines, with 100% air exhaust.

Products Features

  • Motorized operation for Front Sash to Open & Close with Limit Switch controls
  • EC Blower for Supply of Air through HEPA Filter
  • Removable Work Top for Cleaning Purpose.
  • Minimum Noise & Vibration

Specification

PARAMETERS SPECIFICATION
MOC
  • SS 304 / 316 or Powder Coated GI
  • SS 304 work table with perforation at front & back which can be removed occasionally for cleaning purpose.
Blower Assembly
  • EC Blower for Supply Air & AC Blower for Exhaust Air.
Side Panels
  • Doubled Wall flushed Glass Side Panels
Front Sash Arrangement
  • Motorized with Sliding arrangement of Toughened Glass with Limit Switch
HEPA Filters
  • Standard HEPA Filter 0.3 Micron for Supply & Exhaust
Pre Filters
  • Pre Filter for Return Air with 10 Micron Air
Velocity
  • 90±20 FPM below HEPA Filter
Pressure Indicator
  • Differential Pressure Gauge / Digital Pressure inbuilt
Standard Fittings
  • Feather touch Panels for Controlling of BSC
  • FL / UV Light - Automatic / Manual Operation
  • Alarm Triggers in case front door is raised more than 8” (i.e. safe clear opening during operation)
  • UV Light with Hour meter
  • DOP Port
  • On / Off Switch for Blower / FL / UV
  • 5/15 amp switch socket for external equipment
  • SS 304 / 316 stands with Levelling Legs
  • SS 304 / 316 – Long elbow of 1 ft. for exhaust duct.
Optional Arrangements
  • Filter Chocked alarm (Audible & Visible)
  • Velocity display with alarm (Audible & Visible)
  • PLC based Control System
  • Digital Pressure Gauge In-built
Power Supply
  • 220 – 230 V (Single Phase), 50 Hz

Download PDF Datasheet

Download PDF

Looking an Adequate Solution for your Company?

Contact us today for free conslutaion or more information.